Application
These cables were developed for making corrections to submersible pumps in drinking water.
The ACS approval allows the cable to be used in drinking water.
Design
1. Conductor: Flexible plain or tinned copper Class 5.
2. Insulation: Special crosslinked elastomer EI4
3. Outer sheath:
- Special crosslinked elastomer EM2
- Colour blue
- Other colours on request
Core colours
- 2 cores (X) = Brown + Blue
- 3 cores (G) = Green-Yellow + Brown + Blue
- 3 cores (X) = Brown + Black + Grey
- 4 cores (G) = Green-Yellow + Brown + Black + Grey
- 4 cores (X) = Blue + Brown + Black + Grey
- 5 cores (G) = Green-Yellow + Blue + Brown + Black + Grey
- 5 cores (X) = Blue + Brown + Black + Grey + Black
Marking
~~~LYONISUB + ~~~ DW.ACS 07RN8-F nb (x ou G) S mm² 269 NEXANS
Nota
Consult us for others sheath colours.
|